- Pump Flow Rate Range: 0.001~10.000mL/min
- Autosampler Injection Range:0-100μL
- High sensitivity detector
- Powerful data processing software
Liquid Chromatograph, HPLC-2025
Descripción
The HPLC-2025 Liquid Chromatograph is a product with higher quality, more reliability and accuracy.
Features
- Reliability
With the reliable design and high-quality components, HPLC-2025 can operate in good condition for a long time
- Precision
The precision and accuracy of the results are guaranteed with the pumping and sampling technology, high sensitivity detector, and powerful data processing software.
- Ease of use
The operation is more convenient and efficient with a variety of user-friendly designs.
HPLC-2025P1/P2/P4 Pump
Features
Precision
- Excellent repeatability
The precise gradient change and retention time are guaranteed with the reciprocating tandem plunger pump and pressure dynamic suppression algorithm. The repeatability of retention time is less than 0.2%.
Reliability
- The reliable design makes service life longer
- Material
The cam is integrally processed from high-hardness alloy steel and combined with high-frequency heat treatment technology, which makes the surface of the cam is more wear-resistant (the hardness is above 55HRC), and the service life is longer.
- Power
The high-power customized motor, NSK bearings, and independent air duct make the power and life even better.
- Gearing
Self-lubricating and wear-resistant materials are used for the piston drive mechanism. Also, the inner wall rifling design prevents the piston from accidentally locking, making the gearing more reliable.
- Plunger
The suspended floating plunger can adapt to the working conditions automatically, which is convenient for disassembly and prevents the eccentric wear of the sealing ring effectively. With the special sealing structure and the automatic cleaning of the plunger, the pump seal is more reliable.
- Ease of use
- Equipped with an online automatic rinsing mechanism.
When the pump is working, the rinsing pump is automatically turned on and runs periodically, which can effectively prevent the crystallization of buffer salts and the growth of microorganisms, and prolong the service life of the plunger and plunger sealing.
- Easy to purge
Both the workstation and the instrument panel are equipped with a purging function, making it easier to purge.
- Intelligent solvent switching to improve efficiency
Equipped with a 4-channel solvent selection valve for binary pump. The solvent can be automatically switched according to the method.
- Independent 4-channel gradient proportioning valve, easy for maintenance
The gradient proportioning valve of the quaternary pump adopts a 4-channel independent design. The intelligent monitoring and diagnosis can realize real-time monitoring and independent replacement of each channel, the whole design can reduce maintenance costs effectively.
Specification
| Flow Rate Range | 0.001mL/min~10.000mL/min |
| Pump Type | Isocratic(P1), Binary(P2), Quaternary(P4) |
| Maximum Pressure | 62MPa |
| Plunger Rinsing | Supported |
HPLC-2025AS Autosampler
Features
- Precision
- Precise injection volume
The autosampler adopts an integrated constant pressure needle and a precise syringe pump, which ensures accurate injection volume and excellent linearity, making the results more precise and accurate.
- Low carryover to make results more accurate
The sampling needle is highly polished for the outer surface and passivated for the inner surface, which can effectively reduce the sample residue. The carryover is much lower when needle washing of the outer and inner surfaces are performed.
- Reliability
- Design of needle
With our integrated constant pressure sampling needle, the air pressure inside and outside the sample bottle can be balanced during sampling; the injection port is set on the sidewall to prevent bottle pad debris from clogging the needle during puncture.
- Design of degassing unit of washing liquid
The built-in autosampler degassing unit can be used for degassing of washing liquid, avoiding interference caused by air bubbles.
- Design of self-compensation injection pump
The maintenance-free self-lubricating guide device and self-compensating sliding screw are used for real-time compensation of the slight wear, and it has excellent motion accuracy and is more durable.
- Ease of use
- Preloaded sample injection mode, the injection time can be shortened to 5s, which greatly improves the efficiency.
- A variety of injection modes combined with sample temperature control technology to satisfy different detection needs such as rare and unstable samples.
- The dehumidification function is optionally equipped to avoid the generation of condensed water, effectively prevent the sample from being diluted, and ensure accurate results.
- The maintenance is more convenient and efficient with the in-front injection valve.
Specification
| Sample Capacity | 108, 2mL(96&384 well plates) |
| Injection Range | 0-100μL |
| Injection Mode | Low-loss, microliter carrying, full-loop |
| Injection Time | Minimum to 5 s |
| Carryover | 0.003% |
| Degassing Unit | Online degassing(optional) |
| Temperature Control | 4-40 ℃(optional) |
HPLC-2025CO Column Oven
Features
- Precision
Precise temperature control ensures good separation and repeatability.
Using fuzzy PID intelligent temperature control algorithm, ban-based air circulation, and multiple insulation layer design, the column temperature is more accurate, stable, and uniform, the temperature stability is ±0.1 ℃, and the temperature for each analysis are constant and consistent.
- Reliability
Triple protection, more safe to use.
Real-time liquid leak protection, intelligent monitoring of Peltier and cavity temperature, over-temperature power-off protection, triple safety protection designs, effectively prevents accidental liquid leakage and dangers caused by over-heating.
Specification
| Operating Principle | Peltier element and fan-based forced air |
| Temperature Range | 5 ℃ above ambient to 85 ℃
10 ℃ below ambient to 85 ℃ |
HPLC-2025UVD UV-Vis Detector
Features
Precision
- Low LOD
The high-throughput optical path, reference subtraction algorithm, and ultra-precise signal acquisition circuit ensure the detector’s excellent sensitivity.
- Wide linearity
The UVD covers a wide linear range of 2.5AU, making it easier to analyze high concentration samples.
Reliability
The transmission type deuterium lamp and static light path allow the light source switching without moving of lamp, which is more reliable.
With the design of the optical unit and the light source module, the service life is much longer.
Ease of use
- Full-band spectral scanning
A full-band spectral scanning can be performed to easily find the optimal absorption wavelength of the target analyte.
- Wavelength time programming
Wavelength can be set for different analytes during different periods, to accomplish the high-sensitivity analysis of complex samples.
- Good maintenance and high safety
- Built-in mercury lamp for wavelength calibration.
- Over-temperature protection of light source.
- Automatic tracking of light energy.
- With in-front light source and flow celland Liquid leak sensor.
Specification
| Light Source | Deuterium(transmission type) and Tungsten lamp |
| Wavelength Range | 190-800nm |
| Wavelength Accuracy | +/- 1nm |
| Wavelength Precision | +/- 0.1nm |
| Linearity | >2.5 AU |
| Wavelength Calibration | Mercury lamp |
HPLC-2025DAD Diode Array Detector
Features
Precision
- Spectral similarity alignment and peak purity determination are performed for precise qualitative and quantitative analysis.
DAD provides full-spectrum information. The compounds can be identified by similarity comparison in the spectral database. Peak purity determination can be performed in the workstation.
- High sensitivity—Close to UV Detector
High sensitivity mode can be performed for low concentration samples, the signal-to-noise ratio of DAD can be reached to the same level of UVD.
- Achieving more accurate inspection data by high-resolution spectra.
When compound detection is performed in high-resolution mode, a finer spectral map can be output for better analysis of complex samples.
Ease of use
- Supports 12-channel real-time data collection
Significantly enhance the analysis efficiency by:
- Up to 12 wavelengths can be set for real-time detection;
- Real-time analysis at a high sampling rate up to 150Hz;
- Full-spectrum detection.
Specification
| Light Source | Deuterium (transmission type) & Tungsten lamp |
| Wavelength Range | 190~800nm |
| Slit Width | 1nm, 2nm, 4nm, 8nm |
| Wavelength Accuracy | +/- 1nm |
| Wavelength Precision | +/- 0.1nm |
| Linearity | > 2.0 AU |
| Wavelength Calibration | Holmium glass |
HPLC-2025FLD Fluorescence Detector
Specification
| Light Source | 150W Xe lamp |
| Wavelength Range(Excitation) | 200 to 850nm Zero order |
| Wavelength Range(Emission) | 250 to 900nm Zero order |
| Detection Sensitivity (Raman peak of water S/N) | S/N ≥ 900 (Baseline method) |
| Wavelength Accuracy | ±3nm |
| Wavelength Repeatability | ±0.5nm |
HPLC-2025ELSD Evaporative Light-Scattering Detector
Specification
| Noise | ≤0.05mV(1.0mL/min 100% Methanol, Gain 1.00) |
| Drift | ≤0.3mV/30 min(1.0mL/min 100% Methanol, Gain 1.00) |
| Min. Detection Limit | ≤5.0×10-6 g/mL(500pg) |
HPLC-2025WS Workstation
Features
User-friendly
- Ease of use: The workstation interface is flat designed to quickly complete method development, data acquisition, data processing, report editing and printing, etc..
Precision
- Powerfuldata-processing capability: Up to 25 integration events and 3 quantitative calculation methods (external standard method, internal standard method, and normalization method) for complex data.
Compliance
- Database storage: With the professional database system, the encryption of original files and security of raw data can be guaranteed.
- Backup and restore: Backup and restore of data can be easily performed in the workstation, which is convenient for users.
- Multi-level user system: Supports customized multi-level system for access to data, ensuring the effectiveness of the system.



Get Social